<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Solar Water Pump &#8211; Shenzhen GretopWay Technology Co.,Ltd.</title>
	<atom:link href="https://www.gretopway.com/ar/product-category/solar-water-pump/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.gretopway.com/ar</link>
	<description></description>
	<lastBuildDate>Thu, 02 Jul 2026 01:45:08 +0000</lastBuildDate>
	<language>ar</language>
	<sy:updateperiod>
	hourly	</sy:updateperiod>
	<sy:updatefrequency>
	1	</sy:updatefrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://www.gretopway.com/wp-content/uploads/2026/06/cropped-gretopway-logo-ico-32x32.png</url>
	<title>Solar Water Pump &#8211; Shenzhen GretopWay Technology Co.,Ltd.</title>
	<link>https://www.gretopway.com/ar</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Solar Aerator Brushless Solar Pump</title>
		<link>https://www.gretopway.com/ar/product/solar-aerator-brushless-solar-pump/</link>
		
		<dc:creator><![CDATA[Gretopway]]></dc:creator>
		<pubDate>Wed, 01 Jul 2026 06:50:09 +0000</pubDate>
				<guid ispermalink="false">https://www.gretopway.com/?post_type=product&#038;p=846</guid>

					<description><![CDATA[<span class="">This solar aerator series includes </span><strong><span class="">Solar Aerator, Solar Paddle Wheel Aerator</span></strong><span class="">, and </span><strong><span class="">Solar Impeller Aerator</span></strong><span class="">, featuring brushless DC motors and available in pure DC (48V–110V) and AC/DC dual‑use (AC220V/DC300V) versions, compatible with PV, grid, or hybrid power systems. Power ratings range from 370W to 2200W, with oxygenation rates of ≥1.1–3.4 kg/h and coverage areas of 666–8000 m². Outlet sizes are 3" or 4". Each unit comes with a DC controller or AC/DC auto‑switching controller (≤2.2kW). Ideal for aquaculture pond aeration, water quality improvement, and water circulation – green energy with zero running costs.</span>]]></description>
										<content:encoded><![CDATA[<h3>Solar Aerator</h3>
<div class="ds-virtual-list-items _6f2c522">
<div class="ds-virtual-list-visible-items">
<div class="_4f9bf79 d7dc56a8 _43c05b5" data-virtual-list-item-key="50">
<div class="ds-message _63c77b1">
<div class="ds-markdown ds-assistant-message-main-content">
<div class="ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9">
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DSA15‑4.5‑48‑370</span></td>
<td><span class="">48V</span></td>
<td><span class="">60V~90V</span></td>
<td><span class="">370W</span></td>
<td><span class="">15m³/h</span></td>
<td><span class="">4.5m</span></td>
<td><span class="">3*</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DSA25‑5‑48‑750</span></td>
<td><span class="">48V</span></td>
<td><span class="">60V~90V</span></td>
<td><span class="">750W</span></td>
<td><span class="">25m³/h</span></td>
<td><span class="">5m</span></td>
<td><span class="">3*</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DSA30‑7‑72‑1100</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V~120V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">30m³/h</span></td>
<td><span class="">7m</span></td>
<td><span class="">3*</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DSA40‑6‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">40m³/h</span></td>
<td><span class="">6m</span></td>
<td><span class="">3*</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DSA55‑5‑300‑2200‑A/D</span></td>
<td><span class="">AC220/DC300V</span></td>
<td><span class="">300V~400V</span></td>
<td><span class="">2200W</span></td>
<td><span class="">55m³/h</span></td>
<td><span class="">5m</span></td>
<td><span class="">4*</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<h3>Solar Air Oxygenator</h3>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Pump Power</span></th>
<th><span class="">Oxygenation Rate (kg/h)</span></th>
<th><span class="">Covering Area (m²)</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DSAO‑48‑750</span></td>
<td><span class="">48V</span></td>
<td><span class="">60V~90V</span></td>
<td><span class="">750W</span></td>
<td><span class="">≥1.1</span></td>
<td><span class="">666~2000</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DSAO‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">≥2.3</span></td>
<td><span class="">2000~4000</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DSAO‑300‑2200~A/D</span></td>
<td><span class="">AC220/DC300V</span></td>
<td><span class="">300V~400V</span></td>
<td><span class="">2200W</span></td>
<td><span class="">≥3.4</span></td>
<td><span class="">2665~5328</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<div class="btnfanyi_area">
<h3 class="showinputwordnum right">Solar Paddle Wheel Aerator</h3>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Oxygenation Rate (kg/h)</span></th>
<th><span class="">Covering Area (m²)</span></th>
<th><span class="">Impeller Quantity</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DSWA2‑48‑750</span></td>
<td><span class="">48V</span></td>
<td><span class="">60V~90V</span></td>
<td><span class="">750W</span></td>
<td><span class="">&gt;1.1</span></td>
<td><span class="">666~3330</span></td>
<td><span class="">2</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DSWA4‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">&gt;1.9</span></td>
<td><span class="">2000~6660</span></td>
<td><span class="">4</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DSWA6‑300‑2200‑A/D</span></td>
<td><span class="">AC220/DC300V</span></td>
<td><span class="">300V~400V</span></td>
<td><span class="">2200W</span></td>
<td><span class="">&gt;2.0</span></td>
<td><span class="">2665~8000</span></td>
<td><span class="">6</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<h3>Solar Impeller Aerator</h3>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Pump Power</span></th>
<th><span class="">Oxygenation Rate (kg/h)</span></th>
<th><span class="">Covering Area (m²)</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DSIA‑48‑750</span></td>
<td><span class="">48V</span></td>
<td><span class="">60V~90V</span></td>
<td><span class="">750W</span></td>
<td><span class="">≥1.1</span></td>
<td><span class="">666~2000</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DSIA‑72‑1100</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V~120V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">≥1.6</span></td>
<td><span class="">2000~2665</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DSIA‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">≥2.3</span></td>
<td><span class="">2000~4000</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DSIA‑300‑2200‑A/D</span></td>
<td><span class="">AC220/DC300V</span></td>
<td><span class="">300V~400V</span></td>
<td><span class="">2200W</span></td>
<td><span class="">≥3.4</span></td>
<td><span class="">2665~5328</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DFSN-A/D(HV) DC &#038; AC/DC &#038; Wide Voltage Brushless Centrifugal Solar Pump</title>
		<link>https://www.gretopway.com/ar/product/dfsn-a-dhv-dc-ac-dc-wide-voltage-brushless-centrifugal-solar-pump/</link>
		
		<dc:creator><![CDATA[Gretopway]]></dc:creator>
		<pubDate>Wed, 01 Jul 2026 06:34:19 +0000</pubDate>
				<guid ispermalink="false">https://www.gretopway.com/?post_type=product&#038;p=843</guid>

					<description><![CDATA[<span class="">The </span><strong><span class="">DFSN and DFSN‑A/D(HV) series</span></strong><span class=""> are DC and AC/DC wide‑voltage brushless centrifugal solar pumps, available in pure DC (24V–110V) and AC/DC wide‑voltage (85V–280V / 100V–350V) versions, compatible with PV, grid, or hybrid power systems. Power ratings range from 400W to 1500W, delivering flows of 16–36 m³/h with maximum heads up to 24 m. Outlet sizes are 2" or 3", and each unit comes with a 0.6 m cable and free spare parts, equipped with a DC controller or AC/DC auto‑switching controller (≤2.2kW). Ideal for surface water supply, irrigation, drainage, and circulation systems in high‑flow, low‑head applications.</span>]]></description>
										<content:encoded><![CDATA[<h3>Technical Data</h3>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DFSN16‑9‑24‑400</span></td>
<td><span class="">24V</span></td>
<td><span class="">30V~48V</span></td>
<td><span class="">400W</span></td>
<td><span class="">16m³/h</span></td>
<td><span class="">9m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;60V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN21‑15‑48‑750</span></td>
<td><span class="">48V</span></td>
<td><span class="">60V~90V</span></td>
<td><span class="">750W</span></td>
<td><span class="">21m³/h</span></td>
<td><span class="">15m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN21‑15‑72‑750</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V~120V</span></td>
<td><span class="">750W</span></td>
<td><span class="">21m³/h</span></td>
<td><span class="">15m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN25‑18‑72‑1100</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V~120V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">25m³/h</span></td>
<td><span class="">18m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN25‑18‑110‑1100</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">25m³/h</span></td>
<td><span class="">18m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN27‑24‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">27m³/h</span></td>
<td><span class="">24m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN28‑12‑72‑750</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V~120V</span></td>
<td><span class="">750W</span></td>
<td><span class="">28m³/h</span></td>
<td><span class="">12m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN32‑15‑72‑1100</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V~120V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">32m³/h</span></td>
<td><span class="">15m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN32‑15‑110‑1100</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">32m³/h</span></td>
<td><span class="">15m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN36‑20‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">36m³/h</span></td>
<td><span class="">20m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage (AC)</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DFSN21‑15‑72‑750‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">100V‑350V</span></td>
<td><span class="">750W</span></td>
<td><span class="">21m³/h</span></td>
<td><span class="">15m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN25‑18‑72‑1100‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">100V‑350V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">25m³/h</span></td>
<td><span class="">18m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN25‑18‑110‑1100‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">25m³/h</span></td>
<td><span class="">18m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN27‑24‑110‑1500‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">27m³/h</span></td>
<td><span class="">24m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN28‑12‑72‑750‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">100V‑350V</span></td>
<td><span class="">750W</span></td>
<td><span class="">28m³/h</span></td>
<td><span class="">12m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN32‑15‑72‑1100‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">100V‑350V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">32m³/h</span></td>
<td><span class="">15m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN32‑15‑110‑1100‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">32m³/h</span></td>
<td><span class="">15m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DFSN36‑20‑110‑1500‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">36m³/h</span></td>
<td><span class="">20m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<h3>Hydraulic Performance Curves</h3>
<p><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-845" src="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3-1.jpg" alt="Hydraulic Performance Curves 3 1" width="1301" height="515" srcset="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3-1.jpg 1301w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3-1-300x119.jpg 300w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3-1-1024x405.jpg 1024w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3-1-768x304.jpg 768w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3-1-18x7.jpg 18w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3-1-1000x396.jpg 1000w" sizes="(max-width: 1301px) 100vw, 1301px" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DWQD-A/D(HV) DC &#038; AC/DC Submersible Solar Pump</title>
		<link>https://www.gretopway.com/ar/product/dwqd-a-dhv-dc-ac-dc-submersible-solar-pump/</link>
		
		<dc:creator><![CDATA[Gretopway]]></dc:creator>
		<pubDate>Wed, 01 Jul 2026 06:24:26 +0000</pubDate>
				<guid ispermalink="false">https://www.gretopway.com/?post_type=product&#038;p=840</guid>

					<description><![CDATA[<span class="">The </span><strong><span class="">DWQD and DWQD‑A/D(HV) series</span></strong><span class=""> are DC and AC/DC dual‑use high‑flow brushless submersible pumps, available in pure DC (72V–110V) and AC/DC wide‑voltage (85V–280V / 110V–350V) versions, compatible with PV, grid, or hybrid power systems. Power ratings range from 750W to 1500W, delivering flows of 17–80 m³/h with maximum heads up to 30 m. Outlet sizes range from 2" to 4", and each unit comes with a 5 m waterproof cable. Ideal for drainage, flood control, irrigation, and water treatment in high‑flow, low‑head applications.</span>]]></description>
										<content:encoded><![CDATA[<h3>Technical Data</h3>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DWQD17‑27‑110‑1100</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">17m³/h</span></td>
<td><span class="">27m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">—</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD20‑30‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">20m³/h</span></td>
<td><span class="">30m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD35‑10‑72‑750</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V~120V</span></td>
<td><span class="">750W</span></td>
<td><span class="">35m³/h</span></td>
<td><span class="">10m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD35‑10‑110‑750</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">750W</span></td>
<td><span class="">35m³/h</span></td>
<td><span class="">10m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD40‑10‑110‑1100</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">40m³/h</span></td>
<td><span class="">10m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD45‑17‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">45m³/h</span></td>
<td><span class="">17m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD50‑10‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">50m³/h</span></td>
<td><span class="">10m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD80‑8‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">80m³/h</span></td>
<td><span class="">8m</span></td>
<td><span class="">4&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage (AC)</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DWQD17‑27‑110‑1100‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">17m³/h</span></td>
<td><span class="">27m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD20‑30‑110‑1500‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">20m³/h</span></td>
<td><span class="">30m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD35‑10‑110‑750‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">750W</span></td>
<td><span class="">35m³/h</span></td>
<td><span class="">10m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD40‑10‑110‑1100‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">40m³/h</span></td>
<td><span class="">10m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD45‑17‑110‑1500‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">45m³/h</span></td>
<td><span class="">17m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD50‑10‑110‑1500‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">50m³/h</span></td>
<td><span class="">10m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DWQD80‑8‑110‑1500‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">80m³/h</span></td>
<td><span class="">8m</span></td>
<td><span class="">4&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<h3>Hydraulic Performance Curves</h3>
<p><img decoding="async" class="alignnone size-full wp-image-841" src="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-4.jpg" alt="Hydraulic Performance Curves 4" width="1326" height="494" srcset="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-4.jpg 1326w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-4-300x112.jpg 300w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-4-1024x381.jpg 1024w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-4-768x286.jpg 768w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-4-18x7.jpg 18w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-4-1000x373.jpg 1000w" sizes="(max-width: 1326px) 100vw, 1326px" /></p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DQD-A/D(HV) &#038; AC/DC Submersible Solar Pump</title>
		<link>https://www.gretopway.com/ar/product/dqd-a-dhv-ac-dc-submersible-solar-pump/</link>
		
		<dc:creator><![CDATA[Gretopway]]></dc:creator>
		<pubDate>Wed, 01 Jul 2026 06:15:40 +0000</pubDate>
				<guid ispermalink="false">https://www.gretopway.com/?post_type=product&#038;p=837</guid>

					<description><![CDATA[<span class="">The </span><strong><span class="">DQD and DQD‑A/D(HV) series</span></strong><span class=""> are DC and AC/DC dual‑use brushless submersible pumps, available in pure DC (24V–110V) and AC/DC wide‑voltage (85V–280V / 110V–350V) versions, compatible with PV, grid, or hybrid power systems. Power ratings range from 300W to 1500W, delivering flows of 5.5–50 m³/h with maximum heads up to 30 m. Outlet sizes range from 1" to 3", and each unit comes with a 5 m waterproof cable. Ideal for drainage, irrigation, water treatment, and low‑head high‑flow water supply applications.</span>]]></description>
										<content:encoded><![CDATA[<h3>Technical Data</h3>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DQD5.5‑14‑24‑300</span></td>
<td><span class="">24V</span></td>
<td><span class="">30V‑48V</span></td>
<td><span class="">300W</span></td>
<td><span class="">5.5m³/h</span></td>
<td><span class="">14m</span></td>
<td><span class="">1&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;60V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD7‑18‑48‑550</span></td>
<td><span class="">48V</span></td>
<td><span class="">60V‑90V</span></td>
<td><span class="">550W</span></td>
<td><span class="">7m³/h</span></td>
<td><span class="">18m</span></td>
<td><span class="">1&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD7‑26‑72‑750</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V‑120V</span></td>
<td><span class="">750W</span></td>
<td><span class="">7m³/h</span></td>
<td><span class="">26m</span></td>
<td><span class="">1&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD7‑26‑110‑750</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V‑150V</span></td>
<td><span class="">750W</span></td>
<td><span class="">7m³/h</span></td>
<td><span class="">26m</span></td>
<td><span class="">1&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD12‑30‑110‑1100</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V‑150V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">12m³/h</span></td>
<td><span class="">30m</span></td>
<td><span class="">1.5&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD25‑25‑110‑1100</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V‑150V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">25m³/h</span></td>
<td><span class="">25m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD30‑28‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V‑150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">30m³/h</span></td>
<td><span class="">28m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD35‑20‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V‑150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">35m³/h</span></td>
<td><span class="">20m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD50‑10‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V‑150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">50m³/h</span></td>
<td><span class="">10m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage (AC)</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Open Circuit Voltage (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DQD7‑26‑110‑750‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">750W</span></td>
<td><span class="">7m³/h</span></td>
<td><span class="">26m</span></td>
<td><span class="">1&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD12‑30‑110‑1000‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">12m³/h</span></td>
<td><span class="">30m</span></td>
<td><span class="">1.5&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD25‑25‑110‑1100‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">25m³/h</span></td>
<td><span class="">25m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD30‑28‑110‑1500‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">30m³/h</span></td>
<td><span class="">28m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD35‑20‑110‑1500‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">35m³/h</span></td>
<td><span class="">20m</span></td>
<td><span class="">2.5&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQD50‑10‑110‑1500‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">50m³/h</span></td>
<td><span class="">10m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">5m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<h3>Hydraulic Performance Curves</h3>
<p><img decoding="async" class="alignnone size-full wp-image-838" src="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2-1.jpg" alt="Hydraulic Performance Curves 2 1" width="1303" height="510" srcset="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2-1.jpg 1303w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2-1-300x117.jpg 300w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2-1-1024x401.jpg 1024w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2-1-768x301.jpg 768w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2-1-18x7.jpg 18w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2-1-1000x391.jpg 1000w" sizes="(max-width: 1303px) 100vw, 1303px" /></p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DLP-A/D &#038; AC/DC Brushless Swimming Pool Solar Pump</title>
		<link>https://www.gretopway.com/ar/product/dlp-a-d-ac-dc-brushless-swimming-pool-solar-pump/</link>
		
		<dc:creator><![CDATA[Gretopway]]></dc:creator>
		<pubDate>Wed, 01 Jul 2026 06:07:21 +0000</pubDate>
				<guid ispermalink="false">https://www.gretopway.com/?post_type=product&#038;p=833</guid>

					<description><![CDATA[<span class="">The </span><strong><span class="">DLP and DLP‑A/D series</span></strong><span class=""> are DC and AC/DC dual‑use brushless swimming pool solar pumps, available in pure DC (48V–110V) and AC/DC wide‑voltage (85V–280V / 100V–350V) versions, compatible with PV, grid, or hybrid power systems. Power ratings range from 500W to 1200W, delivering flows of 15–27 m³/h with maximum heads up to 19 m. Outlet sizes are 2"x2" or 3"x3", and each unit comes with a 2 m cable. Ideal for swimming pool circulation, water feature fountains, and water treatment systems in high‑flow, low‑head applications.</span>]]></description>
										<content:encoded><![CDATA[<h3>Technical Data</h3>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DLP15‑14‑48‑500</span></td>
<td><span class="">48V</span></td>
<td><span class="">60V~90V</span></td>
<td><span class="">500W</span></td>
<td><span class="">15m³/h</span></td>
<td><span class="">14m</span></td>
<td><span class="">2&#8243;×2&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DLP20‑19‑72‑900</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V~120V</span></td>
<td><span class="">900W</span></td>
<td><span class="">20m³/h</span></td>
<td><span class="">19m</span></td>
<td><span class="">2&#8243;×2&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DLP27‑19‑72‑1200</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V~120V</span></td>
<td><span class="">1200W</span></td>
<td><span class="">27m³/h</span></td>
<td><span class="">19m</span></td>
<td><span class="">3&#8243;×3&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DLP27‑19‑110‑1200</span></td>
<td><span class="">110V</span></td>
<td><span class="">110V~150V</span></td>
<td><span class="">1200W</span></td>
<td><span class="">27m³/h</span></td>
<td><span class="">19m</span></td>
<td><span class="">3&#8243;×3&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage (AC)</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Open Circuit Voltage (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DLP20‑19‑72‑900‑A/D</span></td>
<td><span class="">85V‑280V</span></td>
<td><span class="">100V‑350V</span></td>
<td><span class="">900W</span></td>
<td><span class="">20m³/h</span></td>
<td><span class="">19m</span></td>
<td><span class="">2&#8243;×2&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DLP27‑19‑72‑1200‑A/D</span></td>
<td><span class="">85V‑280V</span></td>
<td><span class="">100V‑350V</span></td>
<td><span class="">1200W</span></td>
<td><span class="">27m³/h</span></td>
<td><span class="">19m</span></td>
<td><span class="">3&#8243;×3&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<h3>Hydraulic Performance Curves</h3>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-836" src="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3.jpg" alt="Hydraulic Performance Curves 3" width="1326" height="525" srcset="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3.jpg 1326w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3-300x119.jpg 300w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3-1024x405.jpg 1024w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3-768x304.jpg 768w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3-18x7.jpg 18w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-3-1000x396.jpg 1000w" sizes="(max-width: 1326px) 100vw, 1326px" /></p>
<p>&nbsp;</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DJET-AD DC &#038; AC/DC Brushless Surface Solar Pump</title>
		<link>https://www.gretopway.com/ar/product/djet-ad-dc-ac-dc-brushless-surface-solar-pump/</link>
		
		<dc:creator><![CDATA[Gretopway]]></dc:creator>
		<pubDate>Wed, 01 Jul 2026 05:57:10 +0000</pubDate>
				<guid ispermalink="false">https://www.gretopway.com/?post_type=product&#038;p=830</guid>

					<description><![CDATA[<span class="">The </span><strong><span class="">DJET and DJET‑AD series</span></strong><span class=""> are DC and AC/DC dual‑use brushless surface solar pumps, available in pure DC (48V–72V) and AC/DC wide‑voltage (85V–280V / 100V–350V) versions, compatible with PV, grid, or hybrid power systems. Power ratings range from 370W to 750W, delivering flows of 2.5–3 m³/h with maximum heads up to 55 m. The outlet is 1"x1", and each unit comes with a 2 m cable. Ideal for domestic water supply, small‑scale irrigation, and surface water boosting in low‑flow, medium‑head applications.</span>]]></description>
										<content:encoded><![CDATA[<h3>Technical Data</h3>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DJET2.5‑35‑48‑370</span></td>
<td><span class="">48V</span></td>
<td><span class="">60V~90V</span></td>
<td><span class="">370W</span></td>
<td><span class="">2.5m³/h</span></td>
<td><span class="">35m</span></td>
<td><span class="">1&#8243;×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DJET2.7‑45‑48‑550</span></td>
<td><span class="">48V</span></td>
<td><span class="">60V~90V</span></td>
<td><span class="">550W</span></td>
<td><span class="">2.7m³/h</span></td>
<td><span class="">45m</span></td>
<td><span class="">1&#8243;×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DJET3‑55‑72‑750</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V~120V</span></td>
<td><span class="">750W</span></td>
<td><span class="">3m³/h</span></td>
<td><span class="">55m</span></td>
<td><span class="">1&#8243;×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage (AC)</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Open Circuit Voltage (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DJET3‑55‑72‑750‑A/D</span></td>
<td><span class="">85V‑280V</span></td>
<td><span class="">100V‑350V</span></td>
<td><span class="">750W</span></td>
<td><span class="">3m³/h</span></td>
<td><span class="">55m</span></td>
<td><span class="">1&#8243;×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<h3>Hydraulic Performance Curves</h3>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-831" src="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2.jpg" alt="Hydraulic Performance Curves 2" width="1319" height="501" srcset="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2.jpg 1319w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2-300x114.jpg 300w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2-1024x389.jpg 1024w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2-768x292.jpg 768w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2-18x7.jpg 18w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-2-1000x380.jpg 1000w" sizes="(max-width: 1319px) 100vw, 1319px" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DQB/DZB &#038; AC/DC Brushless Surface Solar Pump</title>
		<link>https://www.gretopway.com/ar/product/dqb-dzb-ac-dc-brushless-surface-solar-pump/</link>
		
		<dc:creator><![CDATA[Gretopway]]></dc:creator>
		<pubDate>Wed, 01 Jul 2026 03:47:57 +0000</pubDate>
				<guid ispermalink="false">https://www.gretopway.com/?post_type=product&#038;p=826</guid>

					<description><![CDATA[<span class="">The </span><strong><span class="">DQB/DQB‑A/D and DZB/DZB‑A/D series</span></strong><span class=""> are DC and AC/DC dual‑use brushless surface solar pumps, available in pure DC (24V–72V) and AC/DC wide‑voltage (85V–280V / 100V–350V) versions, compatible with PV, grid, or hybrid power systems. Power ratings range from 210W to 750W, delivering flows of 2–3 m³/h with maximum heads up to 65 m. The outlet is 1×1", and each unit comes with a 2 m cable. Ideal for domestic water supply, small‑scale irrigation, and surface water transfer in low‑flow, high‑head applications.</span>]]></description>
										<content:encoded><![CDATA[<h3>Technical Data</h3>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DQB2‑25‑24‑210</span></td>
<td><span class="">24V</span></td>
<td><span class="">30V‑48V</span></td>
<td><span class="">210W</span></td>
<td><span class="">2m³/h</span></td>
<td><span class="">25m</span></td>
<td><span class="">1×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;60V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQB2‑30‑24‑280</span></td>
<td><span class="">24V</span></td>
<td><span class="">30V‑48V</span></td>
<td><span class="">280W</span></td>
<td><span class="">2m³/h</span></td>
<td><span class="">30m</span></td>
<td><span class="">1×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;60V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQB3‑50‑48‑550</span></td>
<td><span class="">48V</span></td>
<td><span class="">60V‑90V</span></td>
<td><span class="">550W</span></td>
<td><span class="">3m³/h</span></td>
<td><span class="">50m</span></td>
<td><span class="">1×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DQB3‑65‑72‑750</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V‑120V</span></td>
<td><span class="">750W</span></td>
<td><span class="">3m³/h</span></td>
<td><span class="">65m</span></td>
<td><span class="">1×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DZB2‑25‑24‑210</span></td>
<td><span class="">24V</span></td>
<td><span class="">30V‑48V</span></td>
<td><span class="">210W</span></td>
<td><span class="">2m³/h</span></td>
<td><span class="">25m</span></td>
<td><span class="">1×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;60V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DZB2‑30‑24‑280</span></td>
<td><span class="">24V</span></td>
<td><span class="">30V‑48V</span></td>
<td><span class="">280W</span></td>
<td><span class="">2m³/h</span></td>
<td><span class="">30m</span></td>
<td><span class="">1×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;60V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DZB3‑50‑48‑550</span></td>
<td><span class="">48V</span></td>
<td><span class="">60V‑90V</span></td>
<td><span class="">550W</span></td>
<td><span class="">3m³/h</span></td>
<td><span class="">50m</span></td>
<td><span class="">1×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DZB3‑65‑72‑750</span></td>
<td><span class="">72V</span></td>
<td><span class="">90V‑120V</span></td>
<td><span class="">750W</span></td>
<td><span class="">3m³/h</span></td>
<td><span class="">65m</span></td>
<td><span class="">1×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage (AC)</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Pump Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DQB3‑65‑72‑750‑A/D</span></td>
<td><span class="">85V‑280V</span></td>
<td><span class="">100V‑350V</span></td>
<td><span class="">750W</span></td>
<td><span class="">3m³/h</span></td>
<td><span class="">65m</span></td>
<td><span class="">1×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage (AC)</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Open Circuit Voltage (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DZB3‑65‑72‑750‑A/D</span></td>
<td><span class="">85V‑280V</span></td>
<td><span class="">100V‑350V</span></td>
<td><span class="">750W</span></td>
<td><span class="">3m³/h</span></td>
<td><span class="">65m</span></td>
<td><span class="">1&#8243;×1&#8243;</span></td>
<td><span class="">2m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<h3>Hydraulic Performance Curves</h3>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-829" src="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-1.jpg" alt="Hydraulic Performance Curves 1" width="1331" height="467" srcset="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-1.jpg 1331w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-1-300x105.jpg 300w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-1-1024x359.jpg 1024w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-1-768x269.jpg 768w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-1-18x6.jpg 18w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-1-1000x351.jpg 1000w" sizes="(max-width: 1331px) 100vw, 1331px" /></p>
<p>&nbsp;</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DC &#038; AC/DC &#038; Wide Voltage Brushless Centrifugal Solar Pump</title>
		<link>https://www.gretopway.com/ar/product/dc-ac-dc-wide-voltage-brushless-centrifugal-solar-pump/</link>
		
		<dc:creator><![CDATA[Gretopway]]></dc:creator>
		<pubDate>Wed, 01 Jul 2026 03:32:31 +0000</pubDate>
				<guid ispermalink="false">https://www.gretopway.com/?post_type=product&#038;p=822</guid>

					<description><![CDATA[<span class="">The </span><strong><span class="">DCPM series</span></strong><span class=""> is a DC and AC/DC wide‑voltage brushless centrifugal solar pump, available in pure DC (48V–110V) and AC/DC dual‑use wide‑voltage (85V–280V / 100V–350V) versions, compatible with PV, grid, or hybrid power systems. Power ratings range from 550W to 3000W, delivering flows of 6–85 m³/h with maximum heads up to 28 m. Outlet sizes range from 1" to 5". Each unit includes a DC controller and free spare parts. Ideal for high‑flow surface irrigation, drainage, circulating water supply, and low‑head water transfer applications.</span>]]></description>
										<content:encoded><![CDATA[<h3>Technical Data</h3>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DCPM6‑26‑48‑550</span></td>
<td><span class="">48V</span></td>
<td><span class="">60‑90V</span></td>
<td><span class="">550W</span></td>
<td><span class="">6m³/h</span></td>
<td><span class="">26m</span></td>
<td><span class="">1&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DCPM15‑14‑48‑550</span></td>
<td><span class="">48V</span></td>
<td><span class="">60‑90V</span></td>
<td><span class="">550W</span></td>
<td><span class="">15m³/h</span></td>
<td><span class="">14m</span></td>
<td><span class="">1.5&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;120V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DCPM21‑14‑72‑750</span></td>
<td><span class="">72V</span></td>
<td><span class="">90‑120V</span></td>
<td><span class="">750W</span></td>
<td><span class="">21m³/h</span></td>
<td><span class="">14m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DCPM26‑15‑72‑1100</span></td>
<td><span class="">72V</span></td>
<td><span class="">90‑120V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">26m³/h</span></td>
<td><span class="">15m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;170V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DCPM27‑21‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110‑150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">27m³/h</span></td>
<td><span class="">21m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DCPM50‑17‑110‑1500</span></td>
<td><span class="">110V</span></td>
<td><span class="">110‑150V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">50m³/h</span></td>
<td><span class="">17m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;220V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table>
<thead>
<tr>
<th><span class="">Model</span></th>
<th><span class="">Voltage (AC)</span></th>
<th><span class="">Optimum Input Voltage (DC)</span></th>
<th><span class="">Power</span></th>
<th><span class="">Max. Flow</span></th>
<th><span class="">Max. Head</span></th>
<th><span class="">Outlet</span></th>
<th><span class="">Cable Length</span></th>
<th><span class="">Solar Panel (VOC)</span></th>
<th><span class="">Solar Panel Power</span></th>
</tr>
</thead>
<tbody>
<tr>
<td><span class="">DCPM21‑14‑72‑750‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">100V‑350V</span></td>
<td><span class="">750W</span></td>
<td><span class="">21m³/h</span></td>
<td><span class="">14m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DCPM26‑15‑72‑1100‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">100V‑350V</span></td>
<td><span class="">1100W</span></td>
<td><span class="">26m³/h</span></td>
<td><span class="">15m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DCPM27‑21‑110‑1500‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">27m³/h</span></td>
<td><span class="">21m</span></td>
<td><span class="">2&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DCPM50‑17‑110‑1500‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">110V‑350V</span></td>
<td><span class="">1500W</span></td>
<td><span class="">50m³/h</span></td>
<td><span class="">17m</span></td>
<td><span class="">3&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DCPM60‑20‑200‑2200‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">200V‑350V</span></td>
<td><span class="">2200W</span></td>
<td><span class="">60m³/h</span></td>
<td><span class="">20m</span></td>
<td><span class="">4&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
<tr>
<td><span class="">DCPM85‑28‑300‑3000‑A/D(HV)</span></td>
<td><span class="">85V‑280V(/)</span></td>
<td><span class="">300V‑350V</span></td>
<td><span class="">3000W</span></td>
<td><span class="">85m³/h</span></td>
<td><span class="">28m</span></td>
<td><span class="">5&#8243;</span></td>
<td><span class="">0.6m</span></td>
<td><span class="">&lt;450V</span></td>
<td><span class="">≥1.3 × PUMP POWER</span></td>
</tr>
</tbody>
</table>
<h3>Hydraulic Performance Curves</h3>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-825" src="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves.jpg" alt="Hydraulic Performance Curves" width="1329" height="482" srcset="https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves.jpg 1329w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-300x109.jpg 300w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-1024x371.jpg 1024w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-768x279.jpg 768w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-18x7.jpg 18w, https://www.gretopway.com/wp-content/uploads/2026/07/Hydraulic-Performance-Curves-1000x363.jpg 1000w" sizes="(max-width: 1329px) 100vw, 1329px" /></p>
<p>&nbsp;</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>4500 RPM DIFFUL &#038; WELLUP Water Pump</title>
		<link>https://www.gretopway.com/ar/product/4500-rpm-difful-wellup-water-pump/</link>
		
		<dc:creator><![CDATA[Gretopway]]></dc:creator>
		<pubDate>Wed, 01 Jul 2026 03:05:48 +0000</pubDate>
				<guid ispermalink="false">https://www.gretopway.com/?post_type=product&#038;p=819</guid>

					<description><![CDATA[Featuring a 4500 RPM permanent magnet synchronous motor, perfectly matched with the output characteristics of solar panels, this series delivers higher head and greater flow.

Whether for agricultural irrigation, livestock water supply, landscape projects, or domestic water use, our products provide an efficient, reliable, and economical green water solution.]]></description>
										<content:encoded><![CDATA[Featuring a 4500 RPM permanent magnet synchronous motor, perfectly matched with the output characteristics of solar panels, this series delivers higher head and greater flow.

Whether for agricultural irrigation, livestock water supply, landscape projects, or domestic water use, our products provide an efficient, reliable, and economical green water solution.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>4DGS-A/D 4 Inch High Speed Deep Well Pump</title>
		<link>https://www.gretopway.com/ar/product/4dgs-a-d-4-inch-high-speed-deep-well-pump/</link>
		
		<dc:creator><![CDATA[Gretopway]]></dc:creator>
		<pubDate>Wed, 01 Jul 2026 02:58:02 +0000</pubDate>
				<guid ispermalink="false">https://www.gretopway.com/?post_type=product&#038;p=817</guid>

					<description><![CDATA[<ol>
<li>Permanent magnet DC brushless synchronous motor: The efficiency is increased by 15% - 20%, saving energy consumption.</li>
<li>The whole 304 stainless steel rotor shaft avoids the risk of shaft breakage.</li>
<li>Stainless steel outlet/connector/oil cylinder, with better corrosion resistance.</li>
<li>Japanese NSK bearing, longer working life.</li>
<li>Two deep groove ball bearings are used at the upper end, and two angular contact bearings are used at the lower end, which can withstand greater radial force and axial force.</li>
<li>Two silicon carbide-impregnated graphite mechanical seal of Italian brand, longer service life and deeper submerging depth.</li>
<li>180°C high temperature resistant copper wire, insulation class F.</li>
<li>Cold rolled 600 silicon steel sheet stator and rotor.</li>
<li>The magnet is made of 40SH NdFeB (neodymium iron boron), with a temperature resistance of 150°C.</li>
<li>S/S pump shaft, impellers adopt whole-stage floating wear-resistant and sand-resistant structure.</li>
<li>The whole pump is small volume and strong power, saving the pump installation cost into the well.</li>
</ol>]]></description>
										<content:encoded><![CDATA[<h3>Controller</h3>
<p>(1) Waterproof grade: IP65<br />
(2) Wide open circuit voltage range. AC: 260-528V; DC: 200-780V<br />
(3) Ambient temperature: -15°C~60°C<br />
(4) MPPT function, the solar power utilization rate is higher.<br />
(5) LED displays the power, voltage, current, speed etc working condition.<br />
(6) It can automatically adjust the speed for operation according to the sunlight power, and can also manually adjust the speed for operation according to the actual demand.<br />
(7) Automatic startup and shutdown, without personnel on duty.<br />
(8) Soft start: No impulse current, protect the pump motor.<br />
(9) Over-voltage/undervoltage/over-current/phase loss/short circuit/water shortage/ high temperature protection etc.<br />
(10) Both AC and DC can be used, AC and DC automatic switching function.</p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>